科研 Skill

电刺激伪迹去除

neuro-stim-artifact-recovery

Removes electrical stimulation artifacts from concurrent recordings and quantifies how much neural signal was lost. Use when pulse artifacts or ringing appear during stimulation.

发布者 Codar安全审核通过v0.1.0更新于 2026-11-18

SKILL.md

Stimulation artifact removal and recovery check

Artifact removal always removes some brain signal too, and residual artifact can look like a neural effect. Choose the method for the artifact type, then prove what the pipeline does with a known injected signal.

1. Characterise the artifact

From raw data at a high sampling rate: pulse shape, duration, whether the amplifier saturated (flat tops), decay tail length, and whether the artifact is identical across pulses (enables templates) or varies (position, current, impedance changes).

2. Choose a method

ArtifactMethod
short pulses (TMS, microstimulation, DBS pulses)blank the saturated span and interpolate, then subtract averaged templates per channel; or SSP/PCA on pulse-locked segments
decay tails after TMSICA or exponential fitting after blanking (TESA, ARTIST pipelines)
continuous sinusoidal (tACS)template subtraction with sliding averages or SSP; removal is fundamentally limited because residuals scale with the artifact and are modulated by physiology (Noury et al. 2016)
DBS at fixed frequencynotch at stimulation frequency and harmonics plus aliasing products; analyse bands away from them
recording channels saturateddata are lost for that span; do not interpret it

Keep the same pipeline for sham and real stimulation conditions.

3. Ground-truth injection test

Add a known synthetic signal (for example a 10 Hz burst or an ERP-shaped waveform at realistic amplitude) to the raw data at times overlapping the artifacts, run the full removal pipeline, and compare output with the injected signal: amplitude recovered, phase or latency error, and correlation. Report the time span after each pulse where recovery is poor; effects inside that span are not interpretable.

Also check residual artifact power at the stimulation frequency and its harmonics in sham vs real.

4. Report

Artifact properties, method and parameters, blanked durations, injection-test recovery numbers, residual artifact spectrum, and the analysis window you consider clean.

示例提示词

我的TMS-EEG记录有脉冲伪迹,帮我去除并评估恢复的神经信号。

所属插件

神经科学面向神经科学研究:EEG/MEG、fMRI、BIDS、spike sorting、连接组、脑机接口解码评估、神经刺激安全与公开神经数据检索。

安装该插件会一并获得同领域的 45 个 Skill / MCP。

同插件的其他科研 Skill

常见问题

电刺激伪迹去除能做什么?

Removes electrical stimulation artifacts from concurrent recordings and quantifies how much neural signal was lost. Use when pulse artifacts or ringing appear during stimulation。

如何安装电刺激伪迹去除?

在科搭 Codar 左侧点击「插件」,在「组件」页签搜索「电刺激伪迹去除」并安装;在 Claude Code 或 Codex 中可以发送本页的安装提示词,或下载 Skill 包后解压到 ~/.claude/skills 或 ~/.codex/skills。

电刺激伪迹去除需要哪些权限?

该科研 Skill没有声明额外权限;执行具体操作时仍由 Agent 按自身规则请求确认。

电刺激伪迹去除经过官方审核吗?

是。SpeedSkills 收录的每个版本都会记录内容摘要与权限声明,当前版本已通过安全审核。