科研 Skill

神经设备法规合规映射

neuro-device-regulatory

Maps a neurotech device to the regulatory standards and testing it needs and builds a requirements-to-risk traceability matrix. Use when planning verification or a design review.

发布者 Codar安全审核通过v0.1.0更新于 2026-11-18

SKILL.md

Neurotech device regulatory mapping

Scope: engineering planning support. Classification and submission strategy belong to the regulatory lead and, ideally, an FDA Q-Submission or notified-body discussion.

0. Load the tool reference

Read references/databases-and-tools.md: neurotech FDA product codes, public databases and requirements tools. Look up any product code live with scripts/fda_lookup.py (class, 510(k)/De Novo/PMA records, MAUDE reports, recalls) through openFDA.

1. Describe the device

Intended use and population, implanted or external, recording and/or stimulation, wireless links, software (on-device, app, cloud), power source, materials in contact with tissue and contact duration.

2. Map to standards and guidance

AreaTypical references
Quality systemISO 13485
Risk managementISO 14971 (hazard analysis, risk controls, residual risk)
Software lifecycleIEC 62304 (safety class A/B/C), FDA guidance on content of premarket submissions for device software functions (Basic vs Enhanced documentation)
Electrical safety, EMCIEC 60601-1, IEC 60601-1-2; ISO 14708-1 and -3 for active implants and neurostimulators
BiocompatibilityISO 10993 series per contact type and duration
UsabilityIEC 62366-1
CybersecurityFDA premarket cybersecurity guidance; threat model, SBOM
MRIASTM F2052, F2213, F2182, F2119 for MR conditional labeling
Implanted BCI specificsFDA guidance on implanted BCI devices for patients with paralysis or amputation (2021): non-clinical testing areas and clinical considerations
EUMDR 2017/745 (active implantables are class III), harmonised standards

Check the current versions of each document; they are revised.

3. Plan verification

For each requirement, define the verification method (test, analysis, inspection), acceptance criterion, and the standard clause it serves. Bench areas commonly needed for implanted neural interfaces: electrode and lead mechanical durability, hermeticity and encapsulation lifetime (accelerated ageing), electrochemical stimulation limits, electrical safety and leakage, EMC, wireless performance, MRI safety, software verification, and animal studies where bench tests cannot answer.

4. Traceability matrix

Use assets/trace_matrix_template.csv: requirement ID, requirement, source (user need, standard clause), design output, verification ID and method, result, linked hazard IDs, risk control. Every hazard with a risk control must trace to a requirement and a verification; every safety requirement must trace to a hazard. List gaps.

Output

Device description, applicable standards table with reasons, verification plan, filled traceability matrix with gaps highlighted, and open questions for the regulatory lead.

示例提示词

帮我把这款植入式BCI对应到FDA和ISO14971要求的测试文档清单。

所属插件

神经科学面向神经科学研究:EEG/MEG、fMRI、BIDS、spike sorting、连接组、脑机接口解码评估、神经刺激安全与公开神经数据检索。

安装该插件会一并获得同领域的 45 个 Skill / MCP。

同插件的其他科研 Skill

常见问题

神经设备法规合规映射能做什么?

Maps a neurotech device to the regulatory standards and testing it needs and builds a requirements-to-risk traceability matrix. Use when planning verification or a design review。

如何安装神经设备法规合规映射?

在科搭 Codar 左侧点击「插件」,在「组件」页签搜索「神经设备法规合规映射」并安装;在 Claude Code 或 Codex 中可以发送本页的安装提示词,或下载 Skill 包后解压到 ~/.claude/skills 或 ~/.codex/skills。

神经设备法规合规映射需要哪些权限?

该科研 Skill没有声明额外权限;执行具体操作时仍由 Agent 按自身规则请求确认。

神经设备法规合规映射经过官方审核吗?

是。SpeedSkills 收录的每个版本都会记录内容摘要与权限声明,当前版本已通过安全审核。