科研 Skill
EEG预处理流程审查
neuro-eeg-preprocessing-review
Designs or audits an EEG or MEG preprocessing pipeline in MNE-Python, EEGLAB, FieldTrip or Brainstorm. Use when choosing or reviewing filter, ICA or epoching settings.
SKILL.md
EEG/MEG preprocessing: settings and order
Preprocessing choices can create or remove effects. Use this order and these defaults unless there is a reason not to, and record every choice.
0. Load the toolbox reference
Read the file for the toolbox in use before writing or reviewing code:
| Toolbox | Reference |
|---|---|
| MNE-Python (and MNE-BIDS-Pipeline, MEG Maxwell filtering) | references/mne.md |
| EEGLAB (clean_rawdata, ICLabel, ERPLAB) | references/eeglab.md |
| FieldTrip | references/fieldtrip.md |
| Brainstorm | references/brainstorm.md |
| Moving between toolboxes, or reviewing a methods section | references/equivalents.md |
Each has a working recipe, the toolbox's own traps, and what to report.
Loading files of any format: neuro-file-formats.
1. Recommended order
- Inspect raw data: units, sampling rate, channel types, montage, events.
- Mark bad channels (flat, saturated, noisy; PREP-style criteria) before anything that mixes channels.
- High-pass filter (see 2). Optionally low-pass and resample (resampling needs an anti-alias low-pass; MNE applies one).
- Line-noise removal: notch at line frequency and harmonics, or spectral methods (ZapLine, CleanLine) when you want to keep the band intact.
- Re-reference (average reference only with good head coverage and bad channels excluded or interpolated first).
- ICA: fit on a copy high-passed at 1 Hz (more stable), apply the unmixing to the data you analyse (Winkler et al. 2015). Classify components with ICLabel or EOG/ECG correlation; remove only clear ocular, cardiac, muscle or line components.
- Interpolate bad channels.
- Epoch, then reject or repair epochs (thresholds or Autoreject).
- Baseline-correct (ERPs) or not (decoding: baseline correction can move
effects; see
neuro-bci-decoding-eval).
2. Filter defaults and why
| Analysis | High-pass | Low-pass | Notes |
|---|---|---|---|
| ERP, slow components (P300, N400, CNV) | 0.01-0.1 Hz | 30-40 Hz | above 0.1 Hz distorts and can invert slow ERPs (Acunzo et al. 2012; Tanner et al. 2015) |
| Time-frequency, oscillations | 0.5-1 Hz | above band of interest | |
| Decoding | as low as practical; check time shifts | task dependent | zero-phase filters move effects in time |
| Real-time | causal filters only | see neuro-realtime-bci-pipeline |
Prefer linear-phase FIR (MNE default firwin) with automatic transition
bands. Report filter type, order or length, cutoffs, transition bandwidth,
and causal vs zero-phase (Widmann et al. 2015). Check the impulse response
for ringing if effects sit close to sharp events.
3. Audit checklist for an existing pipeline
- Units and scaling correct (V vs uV)? Montage matches the cap?
- High-pass cutoff appropriate for the components analysed?
- Was a filter applied to epochs instead of continuous data (edge effects)?
- Reference applied before bad-channel handling? Average reference with few channels?
- ICA fitted on data with slow drifts, or on too little data (rule of thumb: many times more samples than channels squared)?
- Components removed on unclear grounds?
- Rejection thresholds identical across conditions, and trial counts balanced or reported per condition?
- Baseline window free of stimulus-related activity?
Output
A table: step, setting, reason, reference. Flag each deviation with its likely effect on the user's analysis.
References
Widmann, Schroger & Maess 2015; Acunzo et al. 2012; Tanner et al. 2015; Winkler et al. 2015; Bigdely-Shamlo et al. 2015 (PREP); Pion-Tonachini et al. 2019 (ICLabel); Jas et al. 2017 (Autoreject).
示例提示词
帮我检查这套EEG滤波重参考和ICA的预处理流程设置是否合理。
所属插件
安装该插件会一并获得同领域的 45 个 Skill / MCP。
同插件的其他科研 Skill
- Allen脑区本体查询Looks up Allen Institute brain region names, acronyms and atlas hierarchy, and picks a BrainGlobe reference atlas. Use when matching region labels across datasets or papers.
- 动物行为姿态追踪Tracks animal pose and behavior from video with DeepLabCut or SLEAP, and extracts kinematic and behavioral event features. Use for markerless tracking or scoring behavior.
- BIDS神经影像数据管理Converts raw EEG or fMRI data to BIDS, validates with bids-validator, and queries or manages datasets with pybids and datalad. Use when organizing or sharing neuroimaging data.
- Brian2脉冲神经网络仿真Simulates LIF, AdEx and Hodgkin-Huxley spiking neuron networks in Brian2, including STDP plasticity and recurrent dynamics. Use when building a spiking network model.
- 钙成像数据分析Processes two-photon or widefield calcium imaging with Suite2p or CaImAn, from motion correction through ROI extraction to dF/F and spike deconvolution. Use for calcium imaging movies.
- 功能连接组图论分析Computes functional connectivity matrices and graph-theory metrics such as modularity and path length from ROI time series. Use when analyzing brain network topology.
- MNE脑电脑磁分析Runs an MNE-Python EEG or MEG pipeline covering preprocessing, ICA cleanup, ERP and time-frequency analysis, and source localization. Use to analyze raw EEG/MEG recordings end to end.
- 神经解码无泄漏评估Guides leakage-free cross-validation of neural decoders, including subject grouping, nested CV, chance levels and confound checks. Use when training or reporting a BCI classifier.
- 电极通道映射校验Checks that EEG, ECoG or probe channel labels and positions match physiology using correlation-distance consistency. Use when montage labels may be swapped or bridged.
- 聚类置换统计检验Explains how to set up and correctly interpret cluster-based permutation tests and TFCE for ERP or time-frequency data. Use to avoid onset or localization overclaims.
- 神经连接性分析核查Guides choice of leakage-robust connectivity measures such as wPLI, imaginary coherency and AEC, with confound controls. Use when reviewing or planning a connectivity analysis.
- 神经数据集陷阱审查Checklist for auditing neural datasets before training: rate and channel consistency, duplicate subjects, label mapping. Use before modeling on a public or lab dataset.
- 神经数据档案库导航Lists neural data archives such as OpenNeuro, DANDI, PhysioNet and MOABB by paradigm, with access tiers and download guidance. Use when finding a dataset for a research question.
- DBS植入物传感数据分析Loads, time-aligns and analyzes sensing data from DBS and bidirectional implants such as Percept and Summit RC+S. Use with implant LFP exports, packet loss or aDBS biomarkers.
- 神经解码器嵌入式移植Ports a neural signal-processing or BCI decoder from Python or MATLAB to fixed-point embedded C on a microcontroller. Use when moving a decoder onto implant or headstage firmware.
- 神经设备法规合规映射Maps a neurotech device to the regulatory standards and testing it needs and builds a requirements-to-risk traceability matrix. Use when planning verification or a design review.
- 神经电极电化学表征Characterizes neural electrodes electrochemically via impedance spectroscopy, cyclic voltammetry and charge-injection limits. Use when comparing electrode coatings or charge capacity.
- 神经记录文件格式转换Opens, inspects and converts neural recording files from EEG, MEG, intracranial and fNIRS acquisition systems. Use when a reader errors or units, rates or events look wrong.
- 神经信号基础模型评估Fairly evaluates pretrained EEG or iEEG foundation models against classical baselines with matched data and splits. Use when fine-tuning or linear-probing a pretrained model.
- 神经记录前端电路设计Designs or reviews analog front ends for neural recording headstages, covering noise budget, CMRR and ADC resolution. Use when choosing an amplifier or debugging a noisy front end.
- 脑机解码器长期稳定性Evaluates intracortical BCI decoders across days using zero-shot and few-shot regimes to quantify drift and recalibration cost. Use to assess decoder stability over sessions.
- 植入设备功耗热预算Budgets power, data rate and tissue heating for implanted or wireless neural interfaces against thermal screening limits. Use when sizing a high-channel-count implant design.
- NeuroKit2生理信号处理Processes physiological biosignals such as ECG, EEG, EDA, RSP, EMG and EOG with NeuroKit2, including HRV and complexity metrics. Use for psychophysiology or multi-modal signal analysis.
- NeuroMorpho神经元形态检索Finds and compares digital neuron reconstructions on NeuroMorpho.Org by region, cell type or species and reads their morphometry. Use when real neuron morphologies are needed.
常见问题
EEG预处理流程审查能做什么?
Designs or audits an EEG or MEG preprocessing pipeline in MNE-Python, EEGLAB, FieldTrip or Brainstorm. Use when choosing or reviewing filter, ICA or epoching settings。
如何安装EEG预处理流程审查?
在科搭 Codar 左侧点击「插件」,在「组件」页签搜索「EEG预处理流程审查」并安装;在 Claude Code 或 Codex 中可以发送本页的安装提示词,或下载 Skill 包后解压到 ~/.claude/skills 或 ~/.codex/skills。
EEG预处理流程审查需要哪些权限?
该科研 Skill没有声明额外权限;执行具体操作时仍由 Agent 按自身规则请求确认。
EEG预处理流程审查经过官方审核吗?
是。SpeedSkills 收录的每个版本都会记录内容摘要与权限声明,当前版本已通过安全审核。