科研 Skill
相位锁定闭环刺激评估
neuro-phase-locked-stim-eval
Designs and evaluates brain-state- or phase-dependent closed-loop stimulation such as phase-locked TMS or tACS. Use when estimating oscillation phase in real time or checking trigger accuracy.
SKILL.md
Phase-locked stimulation: estimate, trigger, verify
Real-time phase estimates are noisy because the filter and Hilbert transform need future samples. Every system must be evaluated against the phase computed offline with full data, at the moments it actually fired.
1. Choose an estimator
| Method | Idea | Notes |
|---|---|---|
| AR forward prediction | band-pass a past window, fit an autoregressive model, predict ahead, take phase at "now" | used for phase-triggered TMS (Zrenner et al. 2018) |
| Educated temporal prediction | learn the typical cycle length per person, extrapolate from the last peak | simple, fast (Shirinpour et al. 2020) |
| Endpoint-corrected Hilbert (ecHT) | causal Hilbert with end-point correction | low latency (Schreglmann et al. 2021) |
| Threshold / peak detection | trigger on slow-wave down-states or burst amplitude | sleep and beta-burst paradigms |
Fix the target band per participant from a resting baseline (individual peak frequency) and include a minimum amplitude gate: phase is undefined when the oscillation is weak.
2. Evaluate against offline ground truth
- Record the raw signal and every trigger time.
- Offline, compute the "true" phase with a zero-phase band-pass and Hilbert on the full recording.
- Stimulation artifacts corrupt the data right after a pulse, so take ground truth from sham or catch triggers (estimator fires, no pulse), or from data before the artifact with care.
- Report the circular mean phase error, the resultant vector length (consistency), the fraction of triggers within +/-30 or +/-45 degrees of target, and how accuracy depends on amplitude (SNR).
3. Timing chain
Add the hardware delay from decision to pulse (stimulator trigger latency) and compensate it in the prediction horizon; measure it with a loopback. A 10 Hz rhythm moves 3.6 degrees per millisecond.
4. Report
Target band and phase, estimator and parameters, amplitude gate, number of real and sham triggers, phase error mean and spread, consistency, accuracy vs amplitude, and the measured hardware delay.
示例提示词
帮我设计一个在慢波相位触发的闭环听觉刺激实验并评估效果。
所属插件
安装该插件会一并获得同领域的 45 个 Skill / MCP。
同插件的其他科研 Skill
- Allen脑区本体查询Looks up Allen Institute brain region names, acronyms and atlas hierarchy, and picks a BrainGlobe reference atlas. Use when matching region labels across datasets or papers.
- 动物行为姿态追踪Tracks animal pose and behavior from video with DeepLabCut or SLEAP, and extracts kinematic and behavioral event features. Use for markerless tracking or scoring behavior.
- BIDS神经影像数据管理Converts raw EEG or fMRI data to BIDS, validates with bids-validator, and queries or manages datasets with pybids and datalad. Use when organizing or sharing neuroimaging data.
- Brian2脉冲神经网络仿真Simulates LIF, AdEx and Hodgkin-Huxley spiking neuron networks in Brian2, including STDP plasticity and recurrent dynamics. Use when building a spiking network model.
- 钙成像数据分析Processes two-photon or widefield calcium imaging with Suite2p or CaImAn, from motion correction through ROI extraction to dF/F and spike deconvolution. Use for calcium imaging movies.
- 功能连接组图论分析Computes functional connectivity matrices and graph-theory metrics such as modularity and path length from ROI time series. Use when analyzing brain network topology.
- MNE脑电脑磁分析Runs an MNE-Python EEG or MEG pipeline covering preprocessing, ICA cleanup, ERP and time-frequency analysis, and source localization. Use to analyze raw EEG/MEG recordings end to end.
- 神经解码无泄漏评估Guides leakage-free cross-validation of neural decoders, including subject grouping, nested CV, chance levels and confound checks. Use when training or reporting a BCI classifier.
- 电极通道映射校验Checks that EEG, ECoG or probe channel labels and positions match physiology using correlation-distance consistency. Use when montage labels may be swapped or bridged.
- 聚类置换统计检验Explains how to set up and correctly interpret cluster-based permutation tests and TFCE for ERP or time-frequency data. Use to avoid onset or localization overclaims.
- 神经连接性分析核查Guides choice of leakage-robust connectivity measures such as wPLI, imaginary coherency and AEC, with confound controls. Use when reviewing or planning a connectivity analysis.
- 神经数据集陷阱审查Checklist for auditing neural datasets before training: rate and channel consistency, duplicate subjects, label mapping. Use before modeling on a public or lab dataset.
- 神经数据档案库导航Lists neural data archives such as OpenNeuro, DANDI, PhysioNet and MOABB by paradigm, with access tiers and download guidance. Use when finding a dataset for a research question.
- DBS植入物传感数据分析Loads, time-aligns and analyzes sensing data from DBS and bidirectional implants such as Percept and Summit RC+S. Use with implant LFP exports, packet loss or aDBS biomarkers.
- 神经解码器嵌入式移植Ports a neural signal-processing or BCI decoder from Python or MATLAB to fixed-point embedded C on a microcontroller. Use when moving a decoder onto implant or headstage firmware.
- 神经设备法规合规映射Maps a neurotech device to the regulatory standards and testing it needs and builds a requirements-to-risk traceability matrix. Use when planning verification or a design review.
- EEG预处理流程审查Designs or audits an EEG or MEG preprocessing pipeline in MNE-Python, EEGLAB, FieldTrip or Brainstorm. Use when choosing or reviewing filter, ICA or epoching settings.
- 神经电极电化学表征Characterizes neural electrodes electrochemically via impedance spectroscopy, cyclic voltammetry and charge-injection limits. Use when comparing electrode coatings or charge capacity.
- 神经记录文件格式转换Opens, inspects and converts neural recording files from EEG, MEG, intracranial and fNIRS acquisition systems. Use when a reader errors or units, rates or events look wrong.
- 神经信号基础模型评估Fairly evaluates pretrained EEG or iEEG foundation models against classical baselines with matched data and splits. Use when fine-tuning or linear-probing a pretrained model.
- 神经记录前端电路设计Designs or reviews analog front ends for neural recording headstages, covering noise budget, CMRR and ADC resolution. Use when choosing an amplifier or debugging a noisy front end.
- 脑机解码器长期稳定性Evaluates intracortical BCI decoders across days using zero-shot and few-shot regimes to quantify drift and recalibration cost. Use to assess decoder stability over sessions.
- 植入设备功耗热预算Budgets power, data rate and tissue heating for implanted or wireless neural interfaces against thermal screening limits. Use when sizing a high-channel-count implant design.
- NeuroKit2生理信号处理Processes physiological biosignals such as ECG, EEG, EDA, RSP, EMG and EOG with NeuroKit2, including HRV and complexity metrics. Use for psychophysiology or multi-modal signal analysis.
常见问题
相位锁定闭环刺激评估能做什么?
Designs and evaluates brain-state- or phase-dependent closed-loop stimulation such as phase-locked TMS or tACS. Use when estimating oscillation phase in real time or checking trigger accuracy。
如何安装相位锁定闭环刺激评估?
在科搭 Codar 左侧点击「插件」,在「组件」页签搜索「相位锁定闭环刺激评估」并安装;在 Claude Code 或 Codex 中可以发送本页的安装提示词,或下载 Skill 包后解压到 ~/.claude/skills 或 ~/.codex/skills。
相位锁定闭环刺激评估需要哪些权限?
该科研 Skill没有声明额外权限;执行具体操作时仍由 Agent 按自身规则请求确认。
相位锁定闭环刺激评估经过官方审核吗?
是。SpeedSkills 收录的每个版本都会记录内容摘要与权限声明,当前版本已通过安全审核。