科研 Skill
神经记录噪声诊断
neuro-noise-detective
Diagnoses noise and artifacts in neural recordings from spectra or raw traces and names the likely source and fix. Use when a recording shows hum, drift or unexplained interference.
SKILL.md
Noise detective
Start from the data, not guesses: compute spectra per channel, then match the pattern to a source. Run the bundled script first; it does the measurements so you only interpret.
python scripts/spectrum_report.py --data raw.npy --fs 1000 [--names names.json] [--line 50]
Input: array of shape (channels, samples) in volts or microvolts (.npy,
or any file MNE can read via --mne-file). Output: line frequency and
harmonics with their size above the noise floor, odd/even harmonic
balance, other narrow peaks, broadband high-frequency and slow-drift power
per channel, flat and saturated channels, and whether each problem is
common to all channels or channel-specific.
Pattern to source
| Pattern | Likely source | Fix |
|---|---|---|
| 50/60 Hz on all channels, similar size | mains pickup; poor ground or reference contact, unshielded cables | fix ground/reference impedance, twist and shorten leads, move mains cables; then notch or ZapLine |
| 50/60 Hz on a few channels | high impedance on those electrodes | re-prep those electrodes |
| strong odd harmonics (150/180, 250/300 Hz) | non-linear loads: switching supplies, dimmers, motors | unplug or move the equipment; battery-power the amplifier |
| narrow peaks not at line multiples | monitor refresh, LED or motor drivers, Wi-Fi/BT duty cycles, stimulator | switch devices off one at a time; check the stimulator clock |
| broadband rise above about 30 Hz, temporal/frontal | muscle (EMG) | relax jaw/neck, reject or ICA |
| very slow drift below 1 Hz, large | sweat, electrode gel drying, cable movement | cooler room, re-prep, secure cables; high-pass |
| same waveform on all channels | reference or ground electrode problem | fix reference/ground |
| step changes or spikes | electrode pops, movement, cable knocks | mark and reject segments |
| flat channel | disconnected, shorted or bridged electrode | check connection; see neuro-channel-map-verifier for bridging |
| clipped values | amplifier range exceeded, DC offset too large | lower gain, re-prep, check DC coupling |
| periodic about 1 Hz sharp peaks | ECG | ICA or regression with ECG channel |
Workflow
- Run the script on a few minutes of raw (unfiltered) data.
- Read whether the issue is common (reference/ground/environment) or channel-specific (that electrode).
- Match the pattern above; propose the hardware fix first, software fix second (software can remove noise but cannot recover saturated data).
- If the user can change the setup, suggest one change at a time and re-measure.
Output
A short diagnosis: symptom with numbers from the report, most likely source, hardware fix, software fix, and how to confirm.
示例提示词
我的EEG记录有50Hz工频干扰和漂移,帮我诊断噪声来源并给修复建议。
所属插件
安装该插件会一并获得同领域的 45 个 Skill / MCP。
同插件的其他科研 Skill
- Allen脑区本体查询Looks up Allen Institute brain region names, acronyms and atlas hierarchy, and picks a BrainGlobe reference atlas. Use when matching region labels across datasets or papers.
- 动物行为姿态追踪Tracks animal pose and behavior from video with DeepLabCut or SLEAP, and extracts kinematic and behavioral event features. Use for markerless tracking or scoring behavior.
- BIDS神经影像数据管理Converts raw EEG or fMRI data to BIDS, validates with bids-validator, and queries or manages datasets with pybids and datalad. Use when organizing or sharing neuroimaging data.
- Brian2脉冲神经网络仿真Simulates LIF, AdEx and Hodgkin-Huxley spiking neuron networks in Brian2, including STDP plasticity and recurrent dynamics. Use when building a spiking network model.
- 钙成像数据分析Processes two-photon or widefield calcium imaging with Suite2p or CaImAn, from motion correction through ROI extraction to dF/F and spike deconvolution. Use for calcium imaging movies.
- 功能连接组图论分析Computes functional connectivity matrices and graph-theory metrics such as modularity and path length from ROI time series. Use when analyzing brain network topology.
- MNE脑电脑磁分析Runs an MNE-Python EEG or MEG pipeline covering preprocessing, ICA cleanup, ERP and time-frequency analysis, and source localization. Use to analyze raw EEG/MEG recordings end to end.
- 神经解码无泄漏评估Guides leakage-free cross-validation of neural decoders, including subject grouping, nested CV, chance levels and confound checks. Use when training or reporting a BCI classifier.
- 电极通道映射校验Checks that EEG, ECoG or probe channel labels and positions match physiology using correlation-distance consistency. Use when montage labels may be swapped or bridged.
- 聚类置换统计检验Explains how to set up and correctly interpret cluster-based permutation tests and TFCE for ERP or time-frequency data. Use to avoid onset or localization overclaims.
- 神经连接性分析核查Guides choice of leakage-robust connectivity measures such as wPLI, imaginary coherency and AEC, with confound controls. Use when reviewing or planning a connectivity analysis.
- 神经数据集陷阱审查Checklist for auditing neural datasets before training: rate and channel consistency, duplicate subjects, label mapping. Use before modeling on a public or lab dataset.
- 神经数据档案库导航Lists neural data archives such as OpenNeuro, DANDI, PhysioNet and MOABB by paradigm, with access tiers and download guidance. Use when finding a dataset for a research question.
- DBS植入物传感数据分析Loads, time-aligns and analyzes sensing data from DBS and bidirectional implants such as Percept and Summit RC+S. Use with implant LFP exports, packet loss or aDBS biomarkers.
- 神经解码器嵌入式移植Ports a neural signal-processing or BCI decoder from Python or MATLAB to fixed-point embedded C on a microcontroller. Use when moving a decoder onto implant or headstage firmware.
- 神经设备法规合规映射Maps a neurotech device to the regulatory standards and testing it needs and builds a requirements-to-risk traceability matrix. Use when planning verification or a design review.
- EEG预处理流程审查Designs or audits an EEG or MEG preprocessing pipeline in MNE-Python, EEGLAB, FieldTrip or Brainstorm. Use when choosing or reviewing filter, ICA or epoching settings.
- 神经电极电化学表征Characterizes neural electrodes electrochemically via impedance spectroscopy, cyclic voltammetry and charge-injection limits. Use when comparing electrode coatings or charge capacity.
- 神经记录文件格式转换Opens, inspects and converts neural recording files from EEG, MEG, intracranial and fNIRS acquisition systems. Use when a reader errors or units, rates or events look wrong.
- 神经信号基础模型评估Fairly evaluates pretrained EEG or iEEG foundation models against classical baselines with matched data and splits. Use when fine-tuning or linear-probing a pretrained model.
- 神经记录前端电路设计Designs or reviews analog front ends for neural recording headstages, covering noise budget, CMRR and ADC resolution. Use when choosing an amplifier or debugging a noisy front end.
- 脑机解码器长期稳定性Evaluates intracortical BCI decoders across days using zero-shot and few-shot regimes to quantify drift and recalibration cost. Use to assess decoder stability over sessions.
- 植入设备功耗热预算Budgets power, data rate and tissue heating for implanted or wireless neural interfaces against thermal screening limits. Use when sizing a high-channel-count implant design.
- NeuroKit2生理信号处理Processes physiological biosignals such as ECG, EEG, EDA, RSP, EMG and EOG with NeuroKit2, including HRV and complexity metrics. Use for psychophysiology or multi-modal signal analysis.
常见问题
神经记录噪声诊断能做什么?
Diagnoses noise and artifacts in neural recordings from spectra or raw traces and names the likely source and fix. Use when a recording shows hum, drift or unexplained interference。
如何安装神经记录噪声诊断?
在科搭 Codar 左侧点击「插件」,在「组件」页签搜索「神经记录噪声诊断」并安装;在 Claude Code 或 Codex 中可以发送本页的安装提示词,或下载 Skill 包后解压到 ~/.claude/skills 或 ~/.codex/skills。
神经记录噪声诊断需要哪些权限?
该科研 Skill没有声明额外权限;执行具体操作时仍由 Agent 按自身规则请求确认。
神经记录噪声诊断经过官方审核吗?
是。SpeedSkills 收录的每个版本都会记录内容摘要与权限声明,当前版本已通过安全审核。