科研 Skill

热分析表征

thermal-analysis

Covers thermal characterization: differential scanning calorimetry, thermogravimetric analysis, and dilatometry. Use for thermal-event or mass-loss analysis.

发布者 Codar安全审核通过v0.1.0更新于 2026-11-18

SKILL.md

Thermal Analysis

Overview

DSC measures heat flow associated with thermal transitions (glass transition, melting, crystallization, curing, decomposition); TGA measures mass change with temperature (decomposition, volatile loss, oxidation); dilatometry measures dimensional change (thermal expansion, sintering shrinkage). All three run a controlled temperature program and extract event-specific quantitative measures from the resulting curve.

When to use this skill

Activate when the request involves:

  • DSC, differential scanning calorimetry, TGA, thermogravimetric analysis, dilatometry
  • Terms: glass transition (Tg), melting point, crystallization, mass loss, coefficient of thermal expansion, heat flow
  • File formats: instrument-specific exports (.dsc, common CSV/TXT exports)
  • "Find the glass transition in this DSC curve," "quantify mass loss steps in this TGA," "compute CTE"

Core usage

DSC — glass transition and melting/crystallization peak detection

import numpy as np
from scipy.signal import find_peaks, savgol_filter

def find_glass_transition(temperature, heat_flow, window=21):
    """Tg appears as a step change (inflection), not a peak — detect via the
    derivative's local extremum, not peak-finding on the raw curve."""
    smoothed = savgol_filter(heat_flow, window, 3)
    derivative = np.gradient(smoothed, temperature)
    inflection_idx = np.argmax(np.abs(derivative))
    return temperature[inflection_idx]  # midpoint-Tg convention — see pitfalls for other conventions

def find_melting_crystallization_peaks(temperature, heat_flow, prominence=0.1):
    """Melting: endothermic peak; crystallization: exothermic peak — sign
    convention depends on instrument software (heat-flow-up vs -down); confirm
    which convention applies before interpreting peak direction."""
    peaks, properties = find_peaks(heat_flow, prominence=prominence)
    return temperature[peaks], properties

TGA — mass-loss step quantification

def quantify_mass_loss_steps(temperature, mass_percent, step_boundaries):
    """step_boundaries: list of (T_start, T_end) tuples bounding each mass-loss
    event, typically identified from the derivative (DTG) curve's peaks."""
    steps = []
    for t_start, t_end in step_boundaries:
        mask = (temperature >= t_start) & (temperature <= t_end)
        mass_lost = mass_percent[mask][0] - mass_percent[mask][-1]
        steps.append({"T_range": (t_start, t_end), "mass_loss_percent": mass_lost})
    return steps

def dtg_curve(temperature, mass_percent):
    """Derivative TGA — sharpens mass-loss steps into peaks, standard for
    identifying step boundaries and overlapping events."""
    return np.gradient(mass_percent, temperature)

Dilatometry — coefficient of thermal expansion (CTE)

def coefficient_of_thermal_expansion(temperature, length, T1, T2, L0):
    """Linear CTE over a temperature range — must specify the range, since CTE is
    rarely constant across a wide temperature span (phase transitions, anisotropy)."""
    mask = (temperature >= T1) & (temperature <= T2)
    delta_L = length[mask][-1] - length[mask][0]
    delta_T = temperature[mask][-1] - temperature[mask][0]
    return (delta_L / L0) / delta_T

Validation & Pitfalls

Canonical reference: Höhne, Hemminger & Flammersheim, Differential Scanning Calorimetry (2nd ed., 2003); ASTM E1356 (DSC glass transition), ASTM E1131 (TGA compositional analysis), and ASTM E228 (dilatometry CTE) for standard measurement conventions.

  • Tg has multiple reporting conventions (onset, midpoint, inflection) that give different numbers from the same curve — state which convention was used; comparing Tg values across studies/instruments without confirming matched conventions is a common source of apparent discrepancy that isn't a real material difference.
  • Heating rate affects observed transition temperatures, sometimes substantially — Tg and crystallization temperature both shift with scan rate (kinetic, not purely thermodynamic, transitions for polymers especially). Report the heating/cooling rate used; don't compare transition temperatures measured at different rates as if rate-independent.
  • TGA mass-loss step boundaries chosen by eye are subjective, especially for overlapping/gradual events — use the DTG (derivative) curve to identify step boundaries systematically rather than reading approximate onset/endset temperatures directly off the raw mass curve.
  • Furnace atmosphere (inert vs. oxidizing) changes TGA decomposition pathways and apparent mass-loss temperatures — a material's TGA curve in air vs. nitrogen can differ substantially (e.g. oxidative vs. purely thermal decomposition); confirm and report the atmosphere used.
  • CTE measured over a wide temperature range that spans a phase transition or Tg gives a physically meaningless average — always report CTE for a bounded range that stays within one physical regime (below Tg, above Tg, etc.), not a single number spanning transitions.

示例提示词

我有一批样品的DSC和TGA曲线,帮我识别玻璃化转变和质量损失事件。

所属插件

材料表征、性能与材料信息学面向实验与数据驱动的材料研究:XRD/电镜/谱学/热分析/力学测试等表征,合成与加工,电化学与半导体表征,相场、CALPHAD 与连续介质力学,材料数据库、特征工程、贝叶斯优化与主动学习,选材与生命周期评价。

安装该插件会一并获得同领域的 42 个 Skill / MCP。

同插件的其他科研 Skill

常见问题

热分析表征能做什么?

Covers thermal characterization: differential scanning calorimetry, thermogravimetric analysis, and dilatometry. Use for thermal-event or mass-loss analysis。

如何安装热分析表征?

在科搭 Codar 左侧点击「插件」,在「组件」页签搜索「热分析表征」并安装;在 Claude Code 或 Codex 中可以发送本页的安装提示词,或下载 Skill 包后解压到 ~/.claude/skills 或 ~/.codex/skills。

热分析表征需要哪些权限?

该科研 Skill没有声明额外权限;执行具体操作时仍由 Agent 按自身规则请求确认。

热分析表征经过官方审核吗?

是。SpeedSkills 收录的每个版本都会记录内容摘要与权限声明,当前版本已通过安全审核。