科研 Skill
流体与材料物性查询
material-properties-db
Looks up temperature-dependent fluid viscosities, densities, and other material properties for pump and heat-transfer calculations. Use when a calculation needs property data at a given temperature.
SKILL.md
Material Properties Database Skill
Query temperature-dependent fluid and material properties essential for pump design, heat transfer, and fluid mechanics calculations. This skill provides verified correlations and empirical data for common engineering fluids.
Overview
Material property databases provide critical data for engineering calculations:
- Fluid Properties: Viscosity, density, surface tension, vapor pressure
- Temperature Dependence: Polynomial fits, Sutherland's law, Andrade equation
- Phase Data: Saturation properties, freezing/boiling points
- Transport Properties: Thermal conductivity, specific heat
- Dimensionless Numbers: Reynolds, Prandtl, kinematic viscosity
This skill focuses on practical correlations for fluids commonly encountered in pumping applications, chemical processing, and HVAC systems.
Common Fluids for Pumps
Water (H₂O)
The most common pumping fluid with well-established properties:
- Temperature Range: 0°C to 100°C (273.15 K to 373.15 K)
- Density: ~1000 kg/m³ (decreases slightly with temperature)
- Viscosity: Highly temperature-dependent (1.79 mPa·s at 0°C to 0.28 mPa·s at 100°C)
- Applications: HVAC, cooling systems, water supply, municipal systems
- Standards: IAPWS-95 formulation (International Association for Properties of Water and Steam)
Hydraulic Oils
Mineral-based and synthetic oils used in hydraulic systems:
- ISO VG Grades: VG 32, VG 46, VG 68, VG 100 (viscosity at 40°C)
- Temperature Range: -20°C to 100°C typical
- Density: 850-900 kg/m³ (relatively constant)
- Viscosity: Strong temperature dependence (follows Walther equation)
- Applications: Hydraulic pumps, power transmission, control systems
- Viscosity Index (VI): Measure of viscosity-temperature relationship (higher = less change)
Lubricating Oils
Engine oils and industrial lubricants:
- SAE Grades: SAE 10W, 20W, 30, 40, 50
- Multigrade: SAE 10W-30, 15W-40, 20W-50
- Temperature Range: -40°C to 150°C
- Density: 870-920 kg/m³
- Viscosity: Engineered for specific temperature ranges
- Applications: Bearings, gearboxes, engines, turbines
Refrigerants
HFC and natural refrigerants for cooling cycles:
- Common: R134a, R410A, R32, R717 (ammonia), R744 (CO₂)
- Temperature Range: -50°C to 70°C typical
- Two-Phase Properties: Critical for evaporators and condensers
- Pressure Dependent: Properties vary significantly with pressure
- Applications: Chillers, air conditioning, heat pumps, industrial refrigeration
- Note: Use CoolProp database for accurate refrigerant properties
Chemicals and Process Fluids
Common industrial chemicals:
- Ethylene Glycol: Antifreeze, heat transfer fluid (-40°C to 100°C)
- Propylene Glycol: Food-grade antifreeze, pharmaceuticals
- Acids/Bases: Sulfuric acid, caustic soda (corrosive, density ~1.2-1.8 kg/L)
- Solvents: Acetone, toluene, methanol, ethanol
- Hydrocarbons: Gasoline, diesel, kerosene, crude oil
- Brines: Sodium chloride, calcium chloride solutions
Gases (Compressed)
For gas handling and pipeline calculations:
- Air: Standard reference fluid (ideal gas at low pressure)
- Natural Gas: Primarily methane, compressible flow
- Nitrogen: Inert atmosphere, purging
- Oxygen: Medical, combustion applications
- Note: Compressibility effects significant at high pressure
Temperature-Dependent Correlations
Viscosity Models
Andrade Equation (Liquids)
Simple exponential model for liquid viscosity:
μ(T) = A · exp(B/T)
Where:
- μ = dynamic viscosity (Pa·s or mPa·s)
- T = absolute temperature (K)
- A, B = fluid-specific constants
Good for: Quick estimates, limited temperature ranges Accuracy: ±5-10% for moderate temperature ranges
Vogel-Fulcher-Tammann Equation (Better for Oils)
More accurate for oils and high-viscosity fluids:
μ(T) = A · exp(B/(T - C))
Where:
- C = typically 95-140 K for oils
- Better fit over wide temperature ranges
Walther Equation (Petroleum Products)
ASTM D341 standard for petroleum oils:
log₁₀(log₁₀(ν + 0.7)) = A - B·log₁₀(T)
Where:
- ν = kinematic viscosity (cSt = mm²/s)
- T = absolute temperature (K)
- A, B = constants from two-point calibration
Used for: ISO VG oils, SAE grades, ASTM viscosity indices Accuracy: Excellent for petroleum products
Sutherland's Law (Gases)
For gas viscosity temperature dependence:
μ(T) = μ₀ · (T/T₀)^(3/2) · (T₀ + S)/(T + S)
Where:
- μ₀ = reference viscosity at T₀
- T₀ = reference temperature (often 273.15 K)
- S = Sutherland constant (K)
- Air: S = 110.4 K
- Nitrogen: S = 111 K
- Oxygen: S = 127 K
Good for: Ideal gases at moderate pressures Range: Valid from ~100 K to 2000 K
Density Models
Linear Approximation (Liquids)
For incompressible liquids over moderate temperature ranges:
ρ(T) = ρ₀ · [1 - β(T - T₀)]
Where:
- ρ₀ = density at reference temperature T₀ (kg/m³)
- β = volumetric thermal expansion coefficient (1/K)
- Water: β ≈ 0.0002 K⁻¹ near 20°C
- Oils: β ≈ 0.0007 K⁻¹
Polynomial Fit (Water)
IAPWS-IF97 simplified for atmospheric pressure:
ρ(T) = a₀ + a₁·T + a₂·T² + a₃·T³
For water (0-100°C at 1 atm):
- High accuracy (±0.01%)
- Coefficients from NIST or steam tables
Ideal Gas Law (Gases)
For gases at low to moderate pressure:
ρ = P·M / (R·T)
Where:
- P = absolute pressure (Pa)
- M = molar mass (kg/mol)
- R = universal gas constant = 8.314 J/(mol·K)
- T = absolute temperature (K)
Vapor Pressure Models
Antoine Equation
Most common correlation for vapor pressure:
log₁₀(P_vap) = A - B/(T + C)
Where:
- P_vap = vapor pressure (mmHg, kPa, or bar depending on constants)
- T = temperature (°C or K, depending on constants)
- A, B, C = fluid-specific constants
Common fluids (T in °C, P in mmHg):
- Water: A=8.07131, B=1730.63, C=233.426 (1-100°C)
- Ethanol: A=8.04494, B=1554.3, C=222.65 (20-93°C)
- Methanol: A=7.89750, B=1474.08, C=229.13
Applications:
- NPSH calculations (Net Positive Suction Head)
- Cavitation prediction
- Flash point estimation
- Boiling point at altitude
Clausius-Clapeyron Equation
Thermodynamic basis for vapor pressure:
ln(P₂/P₁) = -ΔH_vap/R · (1/T₂ - 1/T₁)
Where:
- ΔH_vap = heat of vaporization (J/mol)
- R = gas constant = 8.314 J/(mol·K)
Good for: Extrapolation from known point, theoretical calculations
Kinematic Viscosity
Relationship between dynamic and kinematic viscosity:
ν = μ / ρ
Where:
- ν = kinematic viscosity (m²/s or cSt)
- μ = dynamic viscosity (Pa·s)
- ρ = density (kg/m³)
- Conversion: 1 cSt = 1 mm²/s = 10⁻⁶ m²/s
Important for:
- Reynolds number calculations
- ISO VG oil ratings (viscosity at 40°C in cSt)
- Viscometer measurements
Data Sources and Standards
Primary Sources
NIST (National Institute of Standards and Technology)
- NIST Chemistry WebBook: https://webbook.nist.gov/chemistry/
- Properties: Thermophysical data for thousands of compounds
- Accuracy: Research-grade, high reliability
- Coverage: Density, viscosity, vapor pressure, thermal properties
IAPWS (International Association for Properties of Water and Steam)
- IAPWS-95: Water and steam properties formulation
- IAPWS-IF97: Industrial formulation (simpler, faster)
- Coverage: 0-1000°C, 0-1000 MPa
- Accuracy: Best available for water/steam
Perry's Chemical Engineers' Handbook
- Publisher: McGraw-Hill
- Content: Comprehensive physical property data
- Correlations: Empirical equations for thousands of fluids
- Industry Standard: Widely used in chemical engineering
ASHRAE Handbooks
- Coverage: HVAC fluids, refrigerants, psychrometrics
- Updates: Annual updates for refrigerants
- Applications: Building systems, refrigeration
Standards Organizations
ASTM International
- ASTM D341: Viscosity-temperature charts for petroleum products
- ASTM D445: Kinematic viscosity measurement
- ASTM D2270: Viscosity index calculation
- ASTM D6751: Biodiesel specifications
ISO (International Organization for Standardization)
- ISO 3448: Industrial liquid lubricant viscosity grades (VG system)
- ISO 12185: Crude petroleum and petroleum products density
- ISO 2909: Petroleum measurement tables
API (American Petroleum Institute)
- API gravity: Oil density scale (°API)
- Technical Data Book: Petroleum refining properties
Software and Databases
CoolProp
- Open-source thermophysical property library
- 100+ pure and pseudo-pure fluids
- High-accuracy equations of state
- See
coolprop-dbskill for details
REFPROP (NIST)
- Reference fluid thermodynamic properties
- Gold standard for accuracy
- Commercial license required
- Based on peer-reviewed equations of state
Engineering Equation Solver (EES)
- Built-in property database
- Automatic unit conversion
- Educational and professional versions
Practical Usage Guidelines
Property Selection for Pump Design
-
Viscosity: Critical for Reynolds number, friction losses
- Use kinematic viscosity (ν) for Re calculations
- Dynamic viscosity (μ) for wall shear stress
-
Density: Affects head-pressure conversion, power requirements
- Use average density for approximate calculations
- Temperature-corrected for accurate NPSH
-
Vapor Pressure: Essential for NPSH available calculations
- Must be evaluated at pumping temperature
- Critical for hot fluids or low suction pressure
-
Specific Gravity: Ratio to water density (dimensionless)
- SG = ρ_fluid / ρ_water @ 4°C
- Simplifies pump curve scaling
Temperature Considerations
- Design Point: Select properties at maximum/minimum operating temperature
- Startup: Consider cold start conditions (high viscosity)
- Seasonal Variation: Account for ambient temperature effects
- Heat Generation: Pump inefficiency adds heat to fluid
Uncertainty and Safety Factors
- Property Uncertainty: ±5% typical for correlations
- Viscosity Range: Design for ±20% variation if uncertain
- NPSH Margin: Add 0.5-1.0 m safety margin above required
- Verification: Always verify critical properties against multiple sources
Query Methods
Manual Calculation
Use empirical equations with fluid-specific constants:
import math
def water_viscosity(T_celsius):
"""Vogel equation for water viscosity"""
A = 0.02414 # mPa·s
B = 247.8 # K
C = 140 # K
T_kelvin = T_celsius + 273.15
mu = A * 10**(B / (T_kelvin - C))
return mu # mPa·s
Tabular Interpolation
Linear or polynomial interpolation from standard tables:
import numpy as np
# Example: Water density table
T_data = np.array([0, 20, 40, 60, 80, 100]) # °C
rho_data = np.array([999.8, 998.2, 992.2, 983.2, 971.8, 958.4]) # kg/m³
def interpolate_density(T):
return np.interp(T, T_data, rho_data)
Database Lookup
Use libraries like CoolProp for high-accuracy data:
from CoolProp.CoolProp import PropsSI
# Water viscosity at 25°C, 1 atm
mu = PropsSI('V', 'T', 298.15, 'P', 101325, 'Water')
Engineering Applications
Reynolds Number Calculation
Re = ρ · v · D / μ = v · D / ν
- Determines flow regime (laminar vs turbulent)
- Critical for friction factor selection
- Typical pump range: Re = 10⁵ to 10⁷
NPSH Available
NPSH_a = (P_atm - P_vap) / (ρ·g) + h_static - h_friction
- Requires vapor pressure at pumping temperature
- Prevents cavitation
- Must exceed NPSH_required by margin
Pressure-Head Conversion
H = ΔP / (ρ·g)
- H = head (m)
- ΔP = pressure rise (Pa)
- ρ = fluid density (kg/m³)
- g = 9.81 m/s²
Power Calculation
P_hydraulic = ρ · g · Q · H
P_shaft = P_hydraulic / η_pump
- Density affects power requirements directly
- Higher specific gravity = higher power
Best Practices
- Always use absolute temperature (Kelvin) for correlations
- Verify units - many correlations use mixed units (°C, mmHg, cSt)
- Check validity range - don't extrapolate beyond calibrated range
- Use multiple sources for critical applications
- Document assumptions - property source, temperature, pressure
- Consider impurities - real fluids differ from pure substance data
- Account for aging - oil degradation changes viscosity over time
- Validate with measurements when possible (viscometer, hydrometer)
Quick Reference Data
Water at Atmospheric Pressure
| T (°C) | ρ (kg/m³) | μ (mPa·s) | ν (mm²/s) | P_vap (kPa) |
|---|---|---|---|---|
| 0 | 999.8 | 1.787 | 1.787 | 0.611 |
| 10 | 999.7 | 1.307 | 1.307 | 1.228 |
| 20 | 998.2 | 1.002 | 1.004 | 2.339 |
| 25 | 997.0 | 0.890 | 0.893 | 3.169 |
| 30 | 995.7 | 0.798 | 0.801 | 4.246 |
| 40 | 992.2 | 0.653 | 0.658 | 7.384 |
| 50 | 988.0 | 0.547 | 0.554 | 12.35 |
| 60 | 983.2 | 0.467 | 0.475 | 19.94 |
| 70 | 977.8 | 0.404 | 0.413 | 31.19 |
| 80 | 971.8 | 0.355 | 0.365 | 47.39 |
| 90 | 965.3 | 0.315 | 0.326 | 70.14 |
| 100 | 958.4 | 0.282 | 0.294 | 101.3 |
Common Oil Viscosities at 40°C
| ISO VG | ν @ 40°C (cSt) | ρ (kg/m³) | μ @ 40°C (mPa·s) |
|---|---|---|---|
| VG 32 | 32 | 865 | 27.7 |
| VG 46 | 46 | 870 | 40.0 |
| VG 68 | 68 | 875 | 59.5 |
| VG 100 | 100 | 880 | 88.0 |
| VG 150 | 150 | 885 | 132.8 |
Sutherland Constants for Common Gases
| Gas | μ₀ @ 273K (μPa·s) | S (K) | Valid Range |
|---|---|---|---|
| Air | 17.16 | 110.4 | 100-1900 K |
| N₂ | 16.66 | 111 | 100-1900 K |
| O₂ | 19.20 | 127 | 100-1900 K |
| CO₂ | 13.73 | 240 | 200-1900 K |
| H₂ | 8.41 | 72 | 100-1900 K |
This skill provides practical correlations and data sources for material properties essential to pump design, fluid mechanics, and thermal engineering applications.
示例提示词
帮我查30摄氏度下乙二醇水溶液的粘度和密度数据。
所属插件
安装该插件会一并获得同领域的 36 个 Skill / MCP。
同插件的其他科研 Skill
- ANSYS Fluent CFD仿真自动化Automates ANSYS Fluent CFD setup, meshing, and batch runs via Python scripting, journal files, and the PyAnsys ecosystem. Use when a user wants to script or automate an ANSYS Fluent simulation.
- Cantera燃烧仿真Runs Cantera combustion simulations: flame temperature, ignition delay, laminar flame speed, PSR. Use for mechanism-based combustion analysis tasks.
- 离心泵气蚀风险评估Calculates NPSHa and NPSHr and assesses cavitation risk for centrifugal pumps, with prevention and detection guidance. Use when sizing suction piping or diagnosing pump cavitation.
- 气蚀评估物性数据库Looks up vapor pressure, NPSHr data, and correlations for cavitation risk assessment in pumps. Use when cavitation-analysis needs reference property or NPSHr data.
- 离心泵设计计算Designs centrifugal pumps from first principles using Euler equations, velocity triangles, and specific speed. Use for impeller sizing or new centrifugal pump design.
- COMSOL多物理场耦合仿真Sets up coupled fluid-structure interaction simulations in COMSOL Multiphysics, focused on pump vibration analysis. Use when a user wants to script or automate a COMSOL FSI model.
- CoolProp流体物性查询Queries thermodynamic and transport properties for 100+ pure and pseudo-pure fluids via the CoolProp library. Use when a calculation needs fluid density, viscosity, or enthalpy data.
- 工程计算环境初始化Sets up a Python session with engineering constants, Pint units, and plotting defaults. Use at the start of a calculation session.
- 流体计算数值错误校验Handles common numerical errors in fluid calculations, such as division by zero and out-of-range physical values, with validation checks. Use when fluid code fails or returns unphysical results.
- 流体力学分析工作流Guides a systematic fluid dynamics analysis from problem setup and domain definition through model selection to validation. Use when planning a CFD or analytical fluid mechanics study end to end.
- 经验公式流体物性速算Computes quick fluid property estimates (density, viscosity, vapor pressure) from empirical correlations without needing a database. Use for fast order-of-magnitude property checks.
- 管道流动与泵选型计算Computes pipe flow, pump sizing, friction factor, and compressible flow results with the fluids Python package. Use for quick, code-based fluid mechanics calculations.
- 工程工具与数据库清点Enumerates installed Python packages, databases, and simulation tools available in the current environment. Use at the start of a session to avoid recommending unavailable tools.
- 管路元件损失系数查询Looks up loss coefficients (K-values) and equivalent lengths for pipes, valves, and fittings in pump and piping systems. Use when computing system head loss.
- 泵性能曲线绘制Creates professional engineering plots such as pump performance curves, CFD velocity contours, and publication-quality figures with matplotlib. Use when a result needs a plotted figure.
- NASA大气与航空流体数据Accesses atmospheric property profiles and standard-atmosphere models from NASA Earthdata for high-altitude and aerospace fluid analysis. Use when a task needs altitude-dependent atmospheric data.
- 管网图论建模Models hydraulic piping networks and multi-pump systems as graphs using NetworkX flow algorithms. Use for analyzing flow distribution across a branched or looped piping network.
- REFPROP高精度物性查询Queries high-accuracy thermodynamic and transport properties from the commercial NIST REFPROP database. Use when a calculation needs reference-quality fluid property data and REFPROP is licensed.
- 数值数组计算Performs numerical array operations with NumPy: velocity field processing, pump curve interpolation, linear systems, and matrix methods. Use for general numerical computation in engineering code.
- OpenFOAM仿真与后处理Runs and post-processes OpenFOAM CFD simulations with PyFoam, pyvista, and vtk for mesh setup, solver control, and visualization. Use for scripted OpenFOAM workflows outside ParaView.
- 泵性能曲线与相似定律Generates and interprets pump H-Q/efficiency/power/NPSH curves, applies affinity laws, and predicts off-design performance. Use for pump curve analysis.
- 工程单位换算与量纲分析Handles engineering units with automatic conversion and dimensional-consistency checking using the Pint library. Use whenever a calculation mixes units or needs unit safety.
- 容积式泵设计分析Designs and analyzes gear, piston, and screw positive-displacement pumps, including volumetric efficiency and slip. Use when the pump is positive-displacement rather than centrifugal.
- 泵效率优化Maximizes pump efficiency through hydraulic design changes and operational strategies such as trimming, VFD control, and system matching. Use when a pump is running inefficiently.
常见问题
流体与材料物性查询能做什么?
Looks up temperature-dependent fluid viscosities, densities, and other material properties for pump and heat-transfer calculations. Use when a calculation needs property data at a given temperature。
如何安装流体与材料物性查询?
在科搭 Codar 左侧点击「插件」,在「组件」页签搜索「流体与材料物性查询」并安装;在 Claude Code 或 Codex 中可以发送本页的安装提示词,或下载 Skill 包后解压到 ~/.claude/skills 或 ~/.codex/skills。
流体与材料物性查询需要哪些权限?
该科研 Skill没有声明额外权限;执行具体操作时仍由 Agent 按自身规则请求确认。
流体与材料物性查询经过官方审核吗?
是。SpeedSkills 收录的每个版本都会记录内容摘要与权限声明,当前版本已通过安全审核。