科研 Skill
管路元件损失系数查询
hydraulic-components-db
Looks up loss coefficients (K-values) and equivalent lengths for pipes, valves, and fittings in pump and piping systems. Use when computing system head loss.
SKILL.md
Hydraulic Components Database Skill
Query loss coefficients (K-values), friction factors, and equivalent lengths for pipes, valves, and fittings essential for piping system design, pump selection, and pressure drop calculations. This skill provides verified data from industry-standard references.
Overview
Hydraulic component databases provide critical data for calculating pressure losses in piping systems:
- Friction Losses: Pipe roughness, friction factors, Moody diagram
- Minor Losses: Valves, fittings, bends, contractions, expansions
- Loss Coefficients (K): Dimensionless resistance values
- Equivalent Length (L/D): Length of straight pipe with equivalent resistance
- System Curves: Total resistance characteristics
- Pump Matching: Ensuring pump operates at design point
This skill focuses on practical data from Crane TP-410, ASHRAE handbooks, and other engineering references commonly used in HVAC, chemical processing, and water distribution systems.
Component Types
Pipes (Major Losses)
Straight pipe friction losses dominate in long piping runs:
Absolute Roughness (ε)
Material roughness affects friction factor in turbulent flow:
| Material | ε (mm) | ε (ft) | Typical Use |
|---|---|---|---|
| Drawn tubing (brass, copper) | 0.0015 | 0.000005 | Clean service, instruments |
| Commercial steel/wrought iron | 0.045 | 0.00015 | General industrial piping |
| Asphalted cast iron | 0.12 | 0.0004 | Water distribution |
| Galvanized iron | 0.15 | 0.0005 | Corrosive service |
| Cast iron (uncoated) | 0.26 | 0.00085 | Municipal water, old systems |
| Concrete (smooth) | 0.3-3.0 | 0.001-0.01 | Large conduits, sewers |
| Riveted steel | 0.9-9.0 | 0.003-0.03 | Old installations |
| PVC, plastic | 0.0015 | 0.000005 | Chemical, water, clean service |
Note: Roughness increases with age due to corrosion, scale, and deposits.
Friction Factor (f)
Dimensionless resistance in Darcy-Weisbach equation:
Laminar Flow (Re < 2300):
f = 64 / Re
Turbulent Flow (Re > 4000): Use Colebrook-White equation (implicit):
1/√f = -2.0 log₁₀(ε/(3.7D) + 2.51/(Re√f))
Or Swamee-Jain approximation (explicit, accurate to ±1%):
f = 0.25 / [log₁₀(ε/(3.7D) + 5.74/Re^0.9)]²
Smooth Pipe Approximations:
- Blasius (Re < 100,000):
f = 0.316 / Re^0.25 - Prandtl-von Karman:
1/√f = 2.0 log₁₀(Re√f) - 0.8
Fully Rough (High Re):
1/√f = -2.0 log₁₀(ε/(3.7D))
Major Loss Calculation
Head loss in straight pipe (Darcy-Weisbach):
h_f = f · (L/D) · (v²/2g)
Where:
- h_f = head loss (m)
- f = Darcy friction factor (dimensionless)
- L = pipe length (m)
- D = pipe inside diameter (m)
- v = average velocity (m/s)
- g = 9.81 m/s²
Pressure Drop:
ΔP = f · (L/D) · (ρv²/2)
- ΔP = pressure drop (Pa)
- ρ = fluid density (kg/m³)
Valves (Minor Losses)
Gate, globe, ball, check, and control valves introduce localized pressure losses.
Gate Valves
Used for on/off service, low pressure drop when fully open:
| Opening | K | L/D | Notes |
|---|---|---|---|
| Fully open | 0.15 | 8 | Minimal obstruction |
| 3/4 open | 0.9 | 40 | Not recommended for throttling |
| 1/2 open | 4.5 | 200 | Severe turbulence |
| 1/4 open | 24 | 1100 | Very high loss |
Applications: Main isolation, block and bleed, rarely for throttling Sizes: DN15 to DN600+ (1/2" to 24"+) Characteristics: Linear flow vs. position when used for throttling (not ideal)
Globe Valves
Higher pressure drop, excellent throttling characteristics:
| Type | K | L/D | Notes |
|---|---|---|---|
| Standard, fully open | 10 | 450 | Y-pattern preferred for low loss |
| Angle valve, fully open | 5 | 200 | 90° turn, lower loss than globe |
| Y-pattern, fully open | 5 | 200 | Streamlined flow path |
Applications: Throttling service, flow regulation, pressure reduction Characteristics: Equal-percentage or linear trim Cavitation: Risk in high-pressure drop applications
Ball Valves
Quarter-turn valves with excellent sealing:
| Type | K | L/D | Notes |
|---|---|---|---|
| Full bore, fully open | 0.05 | 3 | Minimal restriction |
| Reduced bore, fully open | 0.2 | 10 | Smaller port than line size |
| Standard port | 0.2 | 10 | Most common |
Applications: Quick shutoff, clean fluids, low maintenance V-ball: Modified for throttling applications
Check Valves (Non-Return)
Prevent backflow, must overcome cracking pressure:
| Type | K | L/D | Notes |
|---|---|---|---|
| Swing check, fully open | 2.0 | 100 | Low head loss, large sizes |
| Lift check, fully open | 12 | 600 | High loss, globe-valve body |
| Ball check | 70 | 3500 | Small sizes, high loss |
| Wafer check, dual plate | 2.0 | 100 | Compact, low loss |
| Spring-loaded check | 4.5 | 225 | Prevents slam, added resistance |
| Tilting disc check | 1.5 | 50 | Low loss, large diameter |
Important: Check valve K-values assume full flow. Inadequate flow causes partial opening and water hammer.
Butterfly Valves
Used for large diameter, quarter-turn operation:
| Opening | K | L/D | Notes |
|---|---|---|---|
| Fully open | 0.24 | 12 | Depends on disc thickness |
| 60° open | 1.5 | 70 | |
| 40° open | 10 | 500 | Rapid increase in loss |
Applications: HVAC dampers, water treatment, large diameter (DN100-DN3000)
Control Valves
Characterized for precise flow regulation:
| Type | K (open) | C_v Concept | Notes |
|---|---|---|---|
| Linear trim | Variable | Flow ∝ position | Constant ΔP applications |
| Equal % trim | Variable | Flow = k^x | Variable ΔP, better control |
Flow Coefficient (C_v):
Q = C_v · √(ΔP / SG)
- Q = flow rate (GPM)
- ΔP = pressure drop (psi)
- SG = specific gravity
Conversion to K:
K = (d/C_v)² · 890.6
Where d = valve diameter (inches)
Fittings (Minor Losses)
Elbows, tees, reducers, and other direction/size changes.
Standard Elbows
90° bends with various radii:
| Type | K | L/D | Notes |
|---|---|---|---|
| 90° threaded, standard | 1.5 | 75 | r/D ≈ 1 |
| 90° threaded, long radius | 0.75 | 38 | r/D ≈ 1.5, smoother flow |
| 90° flanged, standard | 0.3 | 15 | Larger radius than threaded |
| 90° flanged, long radius | 0.2 | 10 | r/D ≈ 1.5 |
| 90° mitered, no vanes | 1.1 | 55 | Sharp corner, fabricated |
| 45° threaded | 0.4 | 20 | Half the loss of 90° |
| 45° flanged, long radius | 0.2 | 10 |
Radius ratio (r/D): Larger radius = lower loss Multiple elbows: If spaced <10D apart, losses interfere (≈1.5× single elbow)
Tees
Flow through or branch takeoff:
| Configuration | K | L/D | Notes |
|---|---|---|---|
| Threaded tee, flow thru | 0.9 | 45 | Straight-through run |
| Threaded tee, branch | 2.0 | 100 | 90° turn into branch |
| Flanged tee, flow thru | 0.2 | 10 | Lower loss than threaded |
| Flanged tee, branch | 1.0 | 50 | 90° turn |
| Wye, 45° branch | 0.6 | 30 | Smoother transition |
Combining flows: Use energy balance, not simple K addition
Reducers and Expanders
Gradual transitions minimize loss:
Sudden Contraction (larger to smaller):
K = 0.5 · (1 - (D₂/D₁)²)
Based on smaller pipe velocity.
| Area Ratio (A₂/A₁) | K (sudden) | K (gradual) |
|---|---|---|
| 0.8 | 0.09 | 0.05 |
| 0.6 | 0.20 | 0.07 |
| 0.4 | 0.30 | 0.10 |
| 0.2 | 0.40 | 0.12 |
Sudden Expansion (smaller to larger):
K = (1 - (D₁/D₂)²)²
Based on smaller pipe velocity. Higher loss than contraction!
| Area Ratio (A₁/A₂) | K (sudden) | K (gradual) |
|---|---|---|
| 0.8 | 0.04 | 0.02 |
| 0.6 | 0.16 | 0.08 |
| 0.4 | 0.36 | 0.18 |
| 0.2 | 0.64 | 0.30 |
Gradual transitions: Cone angle 7-15° optimum Note: Sudden expansion has Borda-Carnot loss - unrecoverable kinetic energy
Entrances and Exits
Pipe Entrance (from reservoir):
| Type | K | Notes |
|---|---|---|
| Sharp-edged (flush) | 0.5 | Vena contracta forms |
| Slightly rounded | 0.2 | r/D ≈ 0.02 |
| Well-rounded (bellmouth) | 0.04 | r/D ≈ 0.15, minimal loss |
| Inward projecting | 1.0 | Worst case, "Borda mouthpiece" |
Based on pipe velocity.
Pipe Exit (to reservoir):
K = 1.0
All velocity head is lost (kinetic energy unrecovered).
Enlargements and Contractions
Covered above in Reducers section, but key principles:
- Gradual transitions (7-15° cone angle) reduce loss by ~50%
- Expansions create more loss than contractions (irreversible turbulence)
- K-values based on velocity in smaller pipe
- Sudden expansion: K = (1 - β²)² where β = D₁/D₂
- Sudden contraction: K ≈ 0.5(1 - β²)
Example: 4" pipe → 6" pipe (sudden expansion):
- β = 4/6 = 0.667
- K = (1 - 0.667²)² = 0.31 (based on 4" velocity)
Loss Coefficient (K) Method
Definition
Dimensionless coefficient relating pressure drop to velocity head:
h_L = K · (v²/2g)
Where:
- h_L = head loss (m)
- K = loss coefficient (dimensionless)
- v = velocity (m/s)
- g = 9.81 m/s²
Pressure drop form:
ΔP = K · (ρv²/2)
Velocity Reference
Critical: K-value is referenced to a specific velocity!
- Contractions/expansions: Use velocity in smaller pipe
- Fittings: Use velocity in fitting size (same as pipe)
- When converting sizes, velocity changes:
v₂ = v₁ · (D₁/D₂)²
K-Value Addition
For components in series with same diameter:
K_total = K₁ + K₂ + K₃ + ...
Different diameters: Convert to common reference or use ΔP directly.
Limitations
- Assumes turbulent flow (Re > 4000)
- K varies slightly with Reynolds number (often ignored)
- Does not account for compressibility (liquids only)
- Interaction effects when components close together (<10D)
Equivalent Length Method
Definition
Length of straight pipe that produces same loss as fitting:
L_e = K · D / f
Where:
- L_e = equivalent length (m)
- K = loss coefficient
- D = pipe diameter (m)
- f = friction factor
Common approximation: Assume f ≈ 0.02 for quick estimates
L_e/D ≈ K / 0.02 = 50·K
Usage
Add equivalent lengths to actual pipe length:
L_total = L_pipe + ΣL_e
Then calculate total head loss:
h_total = f · (L_total/D) · (v²/2g)
Advantages and Disadvantages
Advantages:
- Simpler for systems with many fittings
- Single friction factor calculation
- Traditional method in piping design
Disadvantages:
- L/D values assume fixed friction factor (usually f ≈ 0.02)
- Less accurate for laminar flow or very rough pipes
- Obscures individual component contributions
- K-method is more fundamental
Typical L/D Values Quick Reference
| Component | L/D (approx) |
|---|---|
| 90° elbow, standard | 30-75 |
| 90° elbow, long radius | 15-20 |
| 45° elbow | 15-20 |
| Tee, flow through | 20-60 |
| Tee, branch flow | 50-100 |
| Gate valve, open | 8-10 |
| Globe valve, open | 300-500 |
| Check valve, swing | 50-100 |
| Ball valve, open | 3-5 |
Note: Values vary by source and pipe size; use manufacturer data when available.
Darcy-Weisbach Equation
Fundamental Form
The cornerstone equation for pipe friction loss:
h_f = f · (L/D) · (v²/2g)
Or in pressure drop form:
ΔP = f · (L/D) · (ρv²/2)
Parameters
- h_f = head loss due to friction (m of fluid column)
- ΔP = pressure drop (Pa or psi)
- f = Darcy friction factor (dimensionless, 4× Fanning factor)
- L = pipe length (m or ft)
- D = pipe inside diameter (m or ft)
- v = average flow velocity (m/s or ft/s)
- g = gravitational acceleration = 9.81 m/s² (32.2 ft/s²)
- ρ = fluid density (kg/m³ or lbm/ft³)
Reynolds Number
Determines flow regime and friction factor:
Re = ρ·v·D / μ = v·D / ν
Where:
- μ = dynamic viscosity (Pa·s)
- ν = kinematic viscosity (m²/s)
Flow Regimes:
- Laminar: Re < 2300 (f = 64/Re)
- Transition: 2300 < Re < 4000 (unstable, avoid for design)
- Turbulent: Re > 4000 (use Moody diagram or correlations)
Friction Factor Determination
Moody Diagram: Graphical solution
- Horizontal axis: Reynolds number (Re)
- Vertical axis: Friction factor (f)
- Parameter: Relative roughness (ε/D)
Colebrook Equation (turbulent, exact but implicit):
1/√f = -2.0 log₁₀(ε/(3.7D) + 2.51/(Re√f))
Requires iterative solution (Newton-Raphson).
Swamee-Jain (explicit approximation, ±1% accurate):
f = 0.25 / [log₁₀(ε/(3.7D) + 5.74/Re^0.9)]²
Valid: 5000 < Re < 10⁸, 10⁻⁶ < ε/D < 10⁻²
Haaland (explicit approximation):
1/√f = -1.8 log₁₀[(ε/(3.7D))^1.11 + 6.9/Re]
Why Darcy-Weisbach?
Advantages over Hazen-Williams:
- Valid for all fluids (not just water)
- Dimensionally consistent
- Valid for all flow regimes
- Accounts for temperature (via viscosity)
- More accurate for non-Newtonian fluids
Hazen-Williams limitations:
- Empirical, water-specific
- Fixed roughness assumption
- Not valid for laminar flow
- Accuracy degrades for viscous fluids
Practical Calculation Steps
- Calculate velocity:
v = Q / A = 4Q / (πD²) - Calculate Reynolds number:
Re = vD/ν - Determine friction factor:
- If Re < 2300:
f = 64/Re - If Re > 4000: Use Swamee-Jain or Moody chart
- If Re < 2300:
- Calculate head loss:
h_f = f(L/D)(v²/2g) - Add minor losses:
h_total = h_f + ΣK(v²/2g)
Minor vs Major Losses
Definitions
Major Losses: Friction in straight pipe
h_major = f · (L/D) · (v²/2g)
- Continuous along pipe length
- Dominant in long piping runs
- Proportional to length
Minor Losses: Valves, fittings, components
h_minor = ΣK · (v²/2g)
- Localized disturbances
- Dominant in short piping with many fittings
- Independent of pipe length
When Each Dominates
Major losses dominate:
- Long straight runs (L/D > 1000)
- Minimal fittings
- Large diameter transmission lines
- Pipeline networks
- Example: Cross-country oil pipeline
Minor losses dominate:
- Short piping with many components
- Compact skid packages
- Manifolds and headers
- Laboratory piping
- Example: Chemical reactor feed system
Design Rules of Thumb
Check both:
h_total = h_major + h_minor
Quick estimate:
- If L/D > 1000 and few fittings: ignore minor losses (error <5%)
- If L/D < 100 with many fittings: minor losses may exceed major losses
- Industrial practice: Calculate both, rarely <10% of total
Pressure drop budget:
- Piping friction: 50-70%
- Fittings and valves: 20-30%
- Equipment (heat exchangers, filters): 20-40%
- Control valve: 25-50% (for good control)
Combined Calculation Example
For 50m of 100mm steel pipe with 4× 90° elbows, 1 gate valve:
Major loss:
- f ≈ 0.018 (assume turbulent, commercial steel)
- h_major = 0.018 × (50/0.1) × (v²/2g) = 9 × (v²/2g)
Minor loss:
- 4 elbows: K = 4 × 0.3 = 1.2
- 1 gate valve: K = 0.15
- K_total = 1.35
- h_minor = 1.35 × (v²/2g)
Total: h_total = 10.35 × (v²/2g)
- Major: 87%
- Minor: 13%
Optimization Considerations
Minimize pressure drop:
- Increase pipe diameter (most effective)
- Use long-radius elbows instead of standard
- Use ball valves instead of globe valves
- Minimize number of fittings
- Avoid sudden contractions/expansions
- Select low-loss check valves
- Clean, smooth pipe interior
Cost trade-off:
- Larger pipe: Higher material cost, lower pumping cost
- Smaller pipe: Lower material cost, higher pumping cost
- Optimize for net present value over equipment life
Data Sources
Crane TP-410 (Primary Reference)
Title: "Flow of Fluids Through Valves, Fittings, and Pipe" Publisher: Crane Co. Technical Paper No. 410 Status: Industry standard since 1942, latest edition 2013
Content:
- Comprehensive K-values for all component types
- Resistance coefficients for valves by size and type
- Pipe friction data and charts
- Worked examples for various fluids
- Cv to K conversions for control valves
- Equivalent length tables
Reliability: Widely accepted in chemical, petroleum, and power industries Availability: Purchase from Crane Co. or technical bookstores Note: Some data considered conservative (over-predicts losses slightly)
ASHRAE Handbooks
ASHRAE Fundamentals Handbook (Chapter on Fluid Flow):
- Pipe sizing for HVAC systems
- Friction loss charts for water, air, refrigerants
- Fitting loss coefficients for HVAC components
- Duct sizing equivalent for air systems
Focus: Building systems, water distribution, chilled water, heating Updates: Revised every 4 years Standards: ASHRAE 90.1 (energy), ASHRAE 62.1 (ventilation)
Other Authoritative Sources
Hydraulic Institute (HI)
- ANSI/HI 9.6.7: Pipe friction loss calculations
- Pump system optimization
- Piping design for pumps
ASME (American Society of Mechanical Engineers)
- B31.1: Power piping code
- B31.3: Process piping code
- Includes pressure drop considerations for safety
Idelchik's Handbook
Title: "Handbook of Hydraulic Resistance" Content:
- Over 6000 coefficients
- Complex geometries
- Research-grade data
- Very comprehensive, academic focus
Cameron Hydraulic Data
Publisher: Flowserve Corporation Content:
- Friction loss tables
- Pump hydraulics
- Piping formulas
- Quick reference for field engineers
Hooper's 2-K Method
Innovation: K varies with size
K = K₁/Re + K∞(1 + K_d/D^0.3)
- More accurate for different pipe sizes
- Accounts for Reynolds number effects
- Used in modern simulation software
Software Tools
PIPE-FLO / AFT Fathom: Commercial pipe network analysis EPANET: Open-source water distribution modeling (EPA) Aspen HYSYS / PRO/II: Process simulation with hydraulics HTRI / HTFS: Heat exchanger and piping thermal-hydraulics Excel add-ins: Many companies have internal spreadsheets
Standards and Testing
ISO 5167: Measurement of fluid flow by means of pressure differential devices AWWA M11: Steel pipe design manual BS 806: UK specifications for pipework systems
Academic References
- White, F.M.: "Fluid Mechanics" - Standard textbook
- Munson, Young, Okiishi: "Fundamentals of Fluid Mechanics"
- Streeter & Wylie: "Fluid Mechanics" - Classic reference
- Karassik's Pump Handbook: Chapter on system hydraulics
Best Practices
Calculation Methodology
- Always calculate both major and minor losses - Don't assume one is negligible
- Use consistent units - SI or Imperial, don't mix
- Reference temperature - Viscosity affects Re and friction factor
- Pipe schedule - Use actual ID, not nominal size
- Future fouling - Add 10-20% margin for aging and deposits
- Elevation changes - Don't forget static head
- Pressure recovery - Expansions have partial recovery (not in K-method)
Design Margins
Pressure drop allowance:
- Add 10-15% for calculation uncertainty
- Add 10-20% for pipe fouling over time
- Add 10-25% for flow variations
- Total margin: 30-50% common in conservative designs
Velocity limits:
- Water/thin liquids: 1-3 m/s (3-10 ft/s)
- Viscous liquids: 0.5-1.5 m/s
- Suction piping: 1-2 m/s (avoid cavitation)
- Steam: 20-50 m/s (higher velocities acceptable)
- Erosion velocity: v < C/√ρ where C ≈ 100-150 (empirical)
Common Errors to Avoid
- Using wrong velocity - K for expansion/contraction uses smaller pipe v
- Ignoring Reynolds number - Laminar vs. turbulent drastically different
- Adding L/D at wrong friction factor - L/D tables assume f ≈ 0.02
- Neglecting entrance/exit losses - K = 0.5 entrance, K = 1.0 exit
- Forgetting elevation - Static head can dominate in vertical piping
- Using nominal diameter - Always use actual inside diameter
- Mixing Darcy and Fanning factors - f_Darcy = 4 × f_Fanning
Documentation
Record in calculations:
- Fluid properties (ρ, μ, temperature)
- Pipe material and schedule (actual ID)
- Flow rate and velocity
- Reynolds number and flow regime
- Friction factor method used
- Each fitting type and K-value
- Source of K-values (Crane TP-410, etc.)
- Safety margins applied
Verification
Sanity checks:
- Does ΔP seem reasonable for application?
- Is velocity within acceptable range?
- Is Re clearly turbulent or laminar (avoid transition)?
- Do fittings account for >5% but <50% of total loss?
- Is NPSH adequate (for pump suction)?
Validation:
- Compare to similar existing systems
- Use multiple methods (K and L_e/D)
- Check with different correlations
- Benchmark against software tools
- Field test after installation
This skill provides comprehensive data and methods for calculating hydraulic losses in piping systems, essential for pump selection, energy analysis, and system design. Data sourced from Crane TP-410, ASHRAE, and other authoritative engineering references.
示例提示词
帮我查一下闸阀全开时的局部损失系数,用于管路水力计算。
所属插件
安装该插件会一并获得同领域的 36 个 Skill / MCP。
同插件的其他科研 Skill
- ANSYS Fluent CFD仿真自动化Automates ANSYS Fluent CFD setup, meshing, and batch runs via Python scripting, journal files, and the PyAnsys ecosystem. Use when a user wants to script or automate an ANSYS Fluent simulation.
- Cantera燃烧仿真Runs Cantera combustion simulations: flame temperature, ignition delay, laminar flame speed, PSR. Use for mechanism-based combustion analysis tasks.
- 离心泵气蚀风险评估Calculates NPSHa and NPSHr and assesses cavitation risk for centrifugal pumps, with prevention and detection guidance. Use when sizing suction piping or diagnosing pump cavitation.
- 气蚀评估物性数据库Looks up vapor pressure, NPSHr data, and correlations for cavitation risk assessment in pumps. Use when cavitation-analysis needs reference property or NPSHr data.
- 离心泵设计计算Designs centrifugal pumps from first principles using Euler equations, velocity triangles, and specific speed. Use for impeller sizing or new centrifugal pump design.
- COMSOL多物理场耦合仿真Sets up coupled fluid-structure interaction simulations in COMSOL Multiphysics, focused on pump vibration analysis. Use when a user wants to script or automate a COMSOL FSI model.
- CoolProp流体物性查询Queries thermodynamic and transport properties for 100+ pure and pseudo-pure fluids via the CoolProp library. Use when a calculation needs fluid density, viscosity, or enthalpy data.
- 工程计算环境初始化Sets up a Python session with engineering constants, Pint units, and plotting defaults. Use at the start of a calculation session.
- 流体计算数值错误校验Handles common numerical errors in fluid calculations, such as division by zero and out-of-range physical values, with validation checks. Use when fluid code fails or returns unphysical results.
- 流体力学分析工作流Guides a systematic fluid dynamics analysis from problem setup and domain definition through model selection to validation. Use when planning a CFD or analytical fluid mechanics study end to end.
- 经验公式流体物性速算Computes quick fluid property estimates (density, viscosity, vapor pressure) from empirical correlations without needing a database. Use for fast order-of-magnitude property checks.
- 管道流动与泵选型计算Computes pipe flow, pump sizing, friction factor, and compressible flow results with the fluids Python package. Use for quick, code-based fluid mechanics calculations.
- 工程工具与数据库清点Enumerates installed Python packages, databases, and simulation tools available in the current environment. Use at the start of a session to avoid recommending unavailable tools.
- 流体与材料物性查询Looks up temperature-dependent fluid viscosities, densities, and other material properties for pump and heat-transfer calculations. Use when a calculation needs property data at a given temperature.
- 泵性能曲线绘制Creates professional engineering plots such as pump performance curves, CFD velocity contours, and publication-quality figures with matplotlib. Use when a result needs a plotted figure.
- NASA大气与航空流体数据Accesses atmospheric property profiles and standard-atmosphere models from NASA Earthdata for high-altitude and aerospace fluid analysis. Use when a task needs altitude-dependent atmospheric data.
- 管网图论建模Models hydraulic piping networks and multi-pump systems as graphs using NetworkX flow algorithms. Use for analyzing flow distribution across a branched or looped piping network.
- REFPROP高精度物性查询Queries high-accuracy thermodynamic and transport properties from the commercial NIST REFPROP database. Use when a calculation needs reference-quality fluid property data and REFPROP is licensed.
- 数值数组计算Performs numerical array operations with NumPy: velocity field processing, pump curve interpolation, linear systems, and matrix methods. Use for general numerical computation in engineering code.
- OpenFOAM仿真与后处理Runs and post-processes OpenFOAM CFD simulations with PyFoam, pyvista, and vtk for mesh setup, solver control, and visualization. Use for scripted OpenFOAM workflows outside ParaView.
- 泵性能曲线与相似定律Generates and interprets pump H-Q/efficiency/power/NPSH curves, applies affinity laws, and predicts off-design performance. Use for pump curve analysis.
- 工程单位换算与量纲分析Handles engineering units with automatic conversion and dimensional-consistency checking using the Pint library. Use whenever a calculation mixes units or needs unit safety.
- 容积式泵设计分析Designs and analyzes gear, piston, and screw positive-displacement pumps, including volumetric efficiency and slip. Use when the pump is positive-displacement rather than centrifugal.
- 泵效率优化Maximizes pump efficiency through hydraulic design changes and operational strategies such as trimming, VFD control, and system matching. Use when a pump is running inefficiently.
常见问题
管路元件损失系数查询能做什么?
Looks up loss coefficients (K-values) and equivalent lengths for pipes, valves, and fittings in pump and piping systems. Use when computing system head loss。
如何安装管路元件损失系数查询?
在科搭 Codar 左侧点击「插件」,在「组件」页签搜索「管路元件损失系数查询」并安装;在 Claude Code 或 Codex 中可以发送本页的安装提示词,或下载 Skill 包后解压到 ~/.claude/skills 或 ~/.codex/skills。
管路元件损失系数查询需要哪些权限?
该科研 Skill没有声明额外权限;执行具体操作时仍由 Agent 按自身规则请求确认。
管路元件损失系数查询经过官方审核吗?
是。SpeedSkills 收录的每个版本都会记录内容摘要与权限声明,当前版本已通过安全审核。